Howell Enterprises, HOME
 
 
PRODUCTS

 

BACKGROUND


CONTACT US


JOBS

 

TESTS



 


 

KALMATRON® KF-A

 Geelong Concrete Testing P/L 

58 Brittania Street,

West Geelong, Australia

Certificate #21807

 (If you would like a copy of the original test, please contact our offices.) 

Sample Tested

Slump

(mm)

Test Date

Age at Test (days)

Mass per unit Volume (Kg/m³)

Compressive Strength MPAs

Control

90

10/07/01

3

2400

13.0

Control

 

10/07/01

3

2400

13.5

Control

 

14/07/01

7

2400

21.0

Control

 

14/07/01

7

2420

21.0

Control

 

4/08/01

28

2420

34.0

 

 

 

 

 

 

Kalmatron®

40

10/07/01

3

2460

15.5

Kalmatron®

 

10/07/01

3

2460

15.5

Kalmatron®

 

14/07/01

7

2460

25.0

Kalmatron®

 

14/07/01

7

2480

25.5

Kalmatron®

 

4/08/01

28

2480

42.5

 Remarks:  (Spec. 25 MPa)            Average of 28 day results:  Control = 34.0  MPa;   Kalmatron® = 42.5 MPa

                                

Top of Page

© Copyright 2000-2007 Howell Enterprises.  All Rights Reserved.

Site Strategy and Design by Brazil Business Services