Qual Tech Test Results, #1206 – Test Site:  Sell’s Point Wastewater Treatment Plant

Test Report #01C-162    NATA Endorsed Report 

Date of Test

Core Dimensions D/H mm

Mass per Unit Volume Kg/m³

Compressive Strength MPas

Corrected Strength due to Height/Diam. Ratio

02/06/01

80.6 X 128

2480

21.5

22.0

 

80.6 X 135

2460

21.0

20.5

 

80.6 X 132

2480

21.5

21.0

 *No defects were noted before or after testing.

A copy of the original test results may be obtained by contacting our office.

(From 13 MPa increase after 3 months)  This is an improvement in compressive strength from the original 13 MPa to a strength of 21 MPa.  This is an increase of 60% after application of Kalmatron® KF-B coating to old concrete.